Key features
- New class of Weather Sensor with high-quality aluminum housing
- Traceable accuracy, due to detailed calibration certificates, performed by an accredited laboratory for every sensor
- Modular architecture, which allows easy maintenance and calibration possibilities for every single sensor
- Drift-free sensing technologies
- Excellent survivability under extreme conditions
- Full-metal construction with ventilated air temperature / humidity measurements
- CMP10 Secondary Standard Kipp & Zonen Pyranometer included
- WiFi-enabled
Accuracy in Detail:
- Temperature better than +/- 0.1°C
- Relative Humidity better than +/- 2%
- Air Pressure better than +/- 0.1 hPa
- Solar Radiation better than 5% W/m2 (secondary standard)
Relative humidity is measured by means of a heated capacitive sensor element; a precision PT100 measuring element is used to measure air temperature. A resonant pressure transducer is employed for precise pressure measurement. Due to the integrated Kipp & Zonen CMP10 pyranometer, global radiation values are in a secondary standard quality.
Lufft WS3100-UMB
£399.99Price
General
Dimensions Ø ca. 250 mm, height approx. 470 mm Weight Approx. 5 kg Interface RS485, 2 - wire, half - duplex/WiFi Power consumption 24 VDC/typical 4W Operating temperature -40...60 °C (optional -60 °C) Operating rel. humidity 0...100 % RH Protection level housing IP66 Global radiation
Principle Pyranometer Unit W/m² Response time < 5s Zero offset A < 7W/m² Zero offset B < 2W/m² Neigungsfehler bei 1000 W/m² < 0.2% Temperature sensivity dependence < 1% (-10°C...40°C) Spectral range (50% points) 285... 2.800nm Measurement range 4000W/m² Temperature
Principle PT100 Measuring range -40 ... 60 °C Unit °C Accuracy ±0.1 °C Resolution 0.01 °C Relative humidity
Principle Capacitive Measuring range 0 ... 100 % RH Unit % RH Accuracy ±2 % RH Resolution 0.1 % RH Air pressure
Principle MEMS Resonant Pressure transducer Measuring range 300 ... 1100 hPa Unit hPa Accuracy ±0.1 hPa Resolution 0.01 hPa